Sandstone Sound-Absorbing Panel Bumning Behavior Test Report

Sandstone Sound-Absorbing Panel Bumning Behavior Test Report

Test Report No.: JCWT20250047571E
Applicant: GuangDong ChuangYa Acoustic Technology Co., LTD
Sample Name: Sandstone sound-absorbing panel
Type and Specification: 1200x600x20 mm Class A2
Contract Category: Applicant Test
Issue Date: 2025-06-16

Sandstone Sound-Absorbing Panel Bumning Behavior Test Report

Sample Name: Sandstone sound-absorbing panel

Trademark: CYATCO

Type/Specification/Grade: 1200x600x20 mm Class A2

Applicant: GuangDong ChuangYa Acoustic Technology Co., LTD

Applicant Address: 10-2, South Industrial City, Shaping Town, Heshan City, Jiangmen City, Guangdong Province

Manufacturer: GuangDong ChuangYa Acoustic Technology Co., LTD

Sampling Way: Samples submitted by the Entrusting Unit

Condition of Sample: Normal

Production Date: 2025.6.5

Contract No.: XZ0506102

Contract Category: Applicant Test

Sample Quantity: 12 ㎡

Entrustment date: 2025-06-10

Sampling/Delivery Date: 2025-06-09

Test Date: 2025-06-12 - 2025-06-16

Test Environment: According to standard requirements

Test Reference: GB 8624-2012 Classification for burning behavior of building materials and products

Judge Reference: GB 8624-2012 Classification for burning behavior of building materials and products

Test Conclusion: The tested item meets the requirements of GB 8624-2012 [Class A (A2-s1, d0), Plate Material].

No Test Item Unit Reference Requirement Test Results Assess
Plate Material Class A (A2-s1, d0)
1 Calorific Value MJ/kg Calorific Value of Homogeneous Product(PCS)≤3.0 1.84 Pass
2 Single burning item test W/s Fire Growth Rate Index, FIGRA0.2MJ
120
0 Pass
___ Flame lateral propagation does not reach the edge of the long wing of the sample. Flame lateral propagation did not reach the edge of the long wing of the sample. Pass
MJ Total Heat Release, THR600s≦ 7.5 0.1 Pass
m2/s2 Smoke Growth Rate Index, SMOGRAS≦30 0 Pass
m2 Total Smoke Production, TSP60os≤ 50 14.1 Pass
___ No flaming droplets/particles within 600 s. No flaming droplets/particles within 600 s. Pass

 